Description
Handy and precise like a Swiss Army Knife
• five gauges: 0.5 / 0.8 / 1.0 / 1.3 /1.6 mm
• easy to insert between key button and the front punching with the guide nose
• double control; haptic and visual
• Swiss made
Exact after-touch can be determined and regulated by introducing gauges of different strengths.
• If the hammer does not let off at the selected level, it is too strong. There is too little after-touch.
• If the hammer moves after let off, the measure is too small. There is too much after-touch.
The after-touch can be determined quickly and set to a specific level according to the customer's requirements. As a rule, the key depth and the let off are regulated first. Then the blow distance is defined based on the desired
after-touch.
Adjustment steps with the after-touch gauge
1. Exact regulation of
• let-off
• key depth
2. Set the blow distance on the sample keys with the after-touch gauge.
3. Adopt the blow distance on all keys.
4. Check step 1 using the after-touch gauge.
• In the event of fluctuations check key depth and let-off.
5. Regulate the key depth of the black keys with the after-touch gauge.
Tip: Even pressure can be recognized by the white coloring of the nail bed.
• five gauges: 0.5 / 0.8 / 1.0 / 1.3 /1.6 mm
• easy to insert between key button and the front punching with the guide nose
• double control; haptic and visual
• Swiss made
Exact after-touch can be determined and regulated by introducing gauges of different strengths.
• If the hammer does not let off at the selected level, it is too strong. There is too little after-touch.
• If the hammer moves after let off, the measure is too small. There is too much after-touch.
The after-touch can be determined quickly and set to a specific level according to the customer's requirements. As a rule, the key depth and the let off are regulated first. Then the blow distance is defined based on the desired
after-touch.
Adjustment steps with the after-touch gauge
1. Exact regulation of
• let-off
• key depth
2. Set the blow distance on the sample keys with the after-touch gauge.
3. Adopt the blow distance on all keys.
4. Check step 1 using the after-touch gauge.
• In the event of fluctuations check key depth and let-off.
5. Regulate the key depth of the black keys with the after-touch gauge.
Tip: Even pressure can be recognized by the white coloring of the nail bed.
Technical data
| Supplier no. | 434292 |
|---|---|
| Weight | 0.2618 kg |
| Unit | pce |
| Categories | 100 / Tools - Equipment / Measuring Tools / regulating Gauges; 100 / Tools - Equipment / Keyboard / key levelling; 100 / Tools - Equipment / Action - regulating / Let-Off - regulating |
Specification